  "verification_date": "2026-09-16",
  "version": "1.2.0",
  "sources": [
    {
      "source_id": "S1",
      "publisher": "Steel Door Institute",
      "title": "Specifications for Standard Steel Doors and Frames (SDI-100)",
      "url": "https://steeldoor.org/ansi-250-8/",
      "edition_or_date": "ANSI/SDI A250.8-2023",
      "locator": "Sections 1.4, 2.1–2.4; Tables 2–4; Appendices A–C",
      "verification_method": "Issuer/publisher HTML read directly",
      "verified": "2026-09-16"
    },
    {
      "source_id": "S2",
      "publisher": "Steel Door Institute",
      "title": "Manufacturing Tolerances for Standard Steel Doors & Frames",
      "url": "https://steeldoor.org/sdi-117/",
      "edition_or_date": "SDI 117-26",
      "locator": "Sections 1, 3.2, 4.1–4.2, 6.2–6.5",
      "verification_method": "Issuer/publisher HTML read directly",
      "verified": "2026-09-16"
    },
    {
      "source_id": "S3",
      "publisher": "Steel Door Institute",
      "title": "Recommended Selection and Usage Guide for Standard Steel Doors",
      "url": "https://steeldoor.org/sdi-108/",
      "edition_or_date": "SDI 108-23",
      "locator": "Table 1 and notes",
      "verification_method": "Issuer/publisher HTML read directly",
      "verified": "2026-09-16"
    },
    {
      "source_id": "S4",
      "publisher": "Steel Door Institute",
      "title": "Test Procedure and Acceptance Criteria for Physical Endurance for Steel Doors, Frames and Frame Anchors",
      "url": "https://steeldoor.org/ansi-250-4/",
      "edition_or_date": "ANSI/SDI A250.4-2026",
      "locator": "Sections 2.2, 5.1, 7.1",
      "verification_method": "Issuer/publisher HTML read directly",
      "verified": "2026-09-16"
    },
    {
      "source_id": "S5",
      "publisher": "DASMA",
      "title": "Technical Data Sheet 154: DASMA Metal Gauge Chart",
      "url": "https://www.dasma.com/wp-content/uploads/2020/06/TDS154-DASMA-Metal-Gauge-Chart.pdf",
      "edition_or_date": "10/9/03; revised 12/10; reaffirmed 09/17",
      "locator": "Steel table, PDF page 2; introduction and references",
      "verification_method": "Issuer PDF text plus table screenshot",
      "verified": "2026-09-16"
    },
    {
      "source_id": "S6",
      "publisher": "DASMA / Karl A. Hermann",
      "title": "The Gauge Controversy Explained",
      "url": "https://www.dasma.com/the-gauge-controversy-explained/",
      "edition_or_date": "Door & Access Systems, Winter 2008, p. 56",
      "locator": "Historical 24-gauge G40 tolerance example",
      "verification_method": "Issuer/publisher HTML read directly",
      "verified": "2026-09-16"
    },
    {
      "source_id": "S7",
      "publisher": "NAAMM / Hollow Metal Manufacturers Association",
      "title": "Guide Specifications for Commercial Hollow Metal Doors and Frames",
      "url": "https://naamm.org/wp-content/uploads/2026/06/hmma_861_14_non_ansi.pdf",
      "edition_or_date": "NAAMM HMMA 861-14; seventh edition, September 15, 2014",
      "locator": "Sections 1.04, 1.05.A.2, 2.01.B, 2.03.B; foreword",
      "verification_method": "Issuer-hosted PDF parsed text read directly; page-image renderer unavailable",
      "verified": "2026-09-16"
    },
    {
      "source_id": "S8",
      "publisher": "NAAMM",
      "title": "HMMA Publications catalogue",
      "url": "https://naamm.org/divisions/hmma/publications/",
      "edition_or_date": "Catalogue checked September 16, 2026",
      "locator": "Listings and issuer download links for HMMA 803-08 and HMMA 861-14",
      "verification_method": "Issuer/publisher HTML read directly",
      "verified": "2026-09-16"
    },
    {
      "source_id": "S9",
      "publisher": "Clopay Building Products",
      "title": "Steel Gauge vs. Decimal Thickness of Steel",
      "url": "https://cdn.clopay.com/public/documents/steel%20gauge%20vs.pdf",
      "edition_or_date": "Undated",
      "locator": "24-gauge worked example; 41.82 lb/ft²/in and 669.12 oz/ft²/in reference constants",
      "verification_method": "Manufacturer PDF text and page 1 screenshot",
      "verified": "2026-09-16"
    },
    {
      "source_id": "S10",
      "publisher": "Steel Source",
      "title": "Gage Table / Tabla de Calibres",
      "url": "https://steelsource.us/gage-tabletabla-de-calibres/",
      "edition_or_date": "Undated",
      "locator": "Galvanized table; Hot Rolled/P&O/Cold Rolled nominal and lower ordering-limit columns; weight formula",
      "verification_method": "Issuer/publisher HTML read directly",
      "verified": "2026-09-16"
    },
    {
      "source_id": "S11",
      "publisher": "National Institute of Standards and Technology",
      "title": "SI Units – Length",
      "url": "https://www.nist.gov/pml/owm/si-units-length",
      "edition_or_date": "Page updated September 19, 2025",
      "locator": "FAQ: exact inch-to-millimeter conversion",
      "verification_method": "Issuer/publisher HTML read directly",
      "verified": "2026-09-16"
    },
    {
      "source_id": "S12",
      "publisher": "Wisconsin Department of Safety and Professional Services",
      "title": "Commercial Buildings",
      "url": "https://dsps.wi.gov/pages/Programs/CommercialBuildings/Default.aspx",
      "edition_or_date": "Live program notice checked September 16, 2026",
      "locator": "2021 ICC adoption September 1, 2025; November 1, 2025 plan-compliance date",
      "verification_method": "Issuer/publisher HTML read directly",
      "verified": "2026-09-16"
    },
    {
      "source_id": "S13",
      "publisher": "Wisconsin Department of Safety and Professional Services",
      "title": "SPS 361 insert pages for the 2021 IBC",
      "url": "https://dsps.wi.gov/Documents/Programs/CommercialBuildings/SPS361Insert.pdf",
      "edition_or_date": "September 1, 2025",
      "locator": "Heading and SPS 361.03(14)",
      "verification_method": "Issuer PDF text and page 2 screenshot",
      "verified": "2026-09-16"
    },
    {
      "source_id": "S14",
      "publisher": "Overhead Door",
      "title": "Rolling Steel Service Doors – Advanced, model 611",
      "url": "https://www.overheaddoor.com/commercial/commercial-details/rolling-steel-service-doors-611",
      "edition_or_date": "Undated live product page",
      "locator": "Curtain specifications and curved-profile options",
      "verification_method": "Issuer/publisher HTML read directly",
      "verified": "2026-09-16"
    },
    {
      "source_id": "S15",
      "publisher": "Conspectus",
      "title": "What thickness is that gage?",
      "url": "https://www.conspectusinc.com/blog/2012/07/what_thickness_is_that_gage",
      "edition_or_date": "July 9, 2012",
      "locator": "Prior published comparison of HMMA and SDI; not used as thickness data",
      "verification_method": "Issuer/publisher HTML read directly",
      "verified": "2026-09-16"
    },
    {
      "source_id": "S16",
      "publisher": "NAAMM / Hollow Metal Manufacturers Association",
      "title": "Steel Tables",
      "url": "https://naamm.org/wp-content/uploads/2026/07/20hmma_803-08.pdf",
      "edition_or_date": "HMMA 803-08 (2008)",
      "locator": "Minimum uncoated-steel thickness table and source/metric notes",
      "verification_method": "Issuer PDF text plus table screenshot",
      "verified": "2026-09-16"
    },
    {
      "source_id": "S17",
      "publisher": "U.S. Government Publishing Office / U.S. Code",
      "title": "15 U.S.C. §206, Standard gauge for sheet and plate iron and steel",
      "url": "https://www.govinfo.gov/link/uscode/15/206",
      "edition_or_date": "Act of March 3, 1893, as reproduced in the linked U.S. Code extract",
      "locator": "Weight per square foot in ounces avoirdupois, gauges 3–30; NOT its thickness column",
      "verification_method": "Official PDF text plus table screenshot",
      "verified": "2026-09-16"
    },
    {
      "source_id": "S18",
      "publisher": "UL Solutions",
      "title": "Doors, Windows and Related Hardware Application Guide",
      "url": "https://www.ul.com/thecodeauthority/knowledge/ul-fire-rated-doors-guide",
      "edition_or_date": "Undated live guide",
      "locator": "Fire-door certification, installation and application",
      "verification_method": "Issuer/publisher HTML read directly",
      "verified": "2026-09-16"
    },
    {
      "source_id": "S19",
      "publisher": "Overhead Door",
      "title": "Insulated Rolling Service Doors, model 626",
      "url": "https://www.overheaddoor.com/commercial/commercial-details/rolling-steel-service-doors-626",
      "edition_or_date": "Undated live product page",
      "locator": "Flat-profile F-265i front and back slat options",
      "verification_method": "Issuer/publisher HTML read directly",
      "verified": "2026-09-16"
    },
    {
      "source_id": "S20",
      "publisher": "UL Solutions",
      "title": "UL Fire Door Inspection and Field Evaluation Programs: What Are the Differences?",
      "url": "https://www.ul.com/resources/ul-fire-door-inspection-and-field-evaluation-programs-what-are-differences",
      "edition_or_date": "Undated live explanation",
      "locator": "Inspection versus field evaluation of modified labelled assemblies",
      "verification_method": "Issuer/publisher HTML read directly",
      "verified": "2026-09-16"
    }
  ],
  "steel_source_galvanized": {
    "8": "0.168",
    "9": "0.153",
    "10": "0.138",
    "11": "0.123",
    "12": "0.108",
    "13": "0.093",
    "14": "0.079",
    "15": "0.071",
    "16": "0.064",
    "17": "0.058",
    "18": "0.052",
    "19": "0.046",
    "20": "0.040",
    "21": "0.037",
    "22": "0.034",
    "23": "0.031",
    "24": "0.028",
    "25": "0.025",
    "26": "0.022",
    "27": "0.020",
    "28": "0.019",
    "29": "0.017",
    "30": "0.016"
  },
  "steel_source_nominal": {
    "3": "0.239",
    "4": "0.224",
    "5": "0.209",
    "6": "0.194",
    "7": "0.179",
    "8": "0.164",
    "9": "0.150",
    "10": "0.135",
    "11": "0.120",
    "12": "0.105",
    "13": "0.090",
    "14": "0.075",
    "15": "0.067",
    "16": "0.060",
    "17": "0.054",
    "18": "0.048",
    "19": "0.042",
    "20": "0.036",
    "21": "0.033",
    "22": "0.030",
    "23": "0.027",
    "24": "0.024",
    "25": "0.021",
    "26": "0.018",
    "27": "0.016",
    "28": "0.015"
  },
  "steel_source_lower_ordering_limit": {
    "3": "0.2281",
    "4": "0.2162",
    "5": "0.2012",
    "6": "0.1863",
    "7": "0.1723",
    "8": "0.1574",
    "9": "0.1425",
    "10": "0.1285",
    "11": "0.1136",
    "12": "0.0986",
    "13": "0.0847",
    "14": "0.0697",
    "15": "0.0623",
    "16": "0.0548",
    "17": "0.0498",
    "18": "0.0438",
    "19": "0.0378",
    "20": "0.0329",
    "21": "0.0299",
    "22": "0.0269",
    "23": "0.0239",
    "24": "0.0209",
    "25": "0.0179",
    "26": "0.0159",
    "27": "0.0144",
    "28": "0.0129"
  },
  "dasma_bare_min": {
    "8": "0.1584",
    "10": "0.1285",
    "11": "0.1136",
    "12": "0.0986",
    "13": "0.0847",
    "14": "0.0697",
    "15": "0.0623",
    "16": "0.0548",
    "17": "0.0498",
    "18": "0.0438",
    "19": "0.0388",
    "20": "0.0329",
    "21": "0.0299",
    "22": "0.0269",
    "23": "0.0239",
    "24": "0.0209",
    "25": "0.0179",
    "26": "0.0159",
    "27": "0.0144",
    "28": "0.0129",
    "29": "0.0115",
    "30": "0.0100"
  },
  "sdi_min": {
    "20": "0.032",
    "18": "0.042",
    "16": "0.053",
    "14": "0.067",
    "12": "0.093",
    "10": "0.123",
    "7": "0.167"
  },
  "hmma_min": {
    "4": "0.214",
    "5": "0.199",
    "6": "0.184",
    "7": "0.167",
    "8": "0.152",
    "10": "0.123",
    "12": "0.093",
    "14": "0.067",
    "16": "0.053",
    "18": "0.042",
    "20": "0.032",
    "22": "0.026",
    "24": "0.020",
    "26": "0.016",
    "28": "0.013"
  },
  "hmma_printed_mm": {
    "4": "5.43",
    "5": "5.05",
    "6": "4.67",
    "7": "4.24",
    "8": "3.86",
    "10": "3.12",
    "12": "2.36",
    "14": "1.70",
    "16": "1.34",
    "18": "1.06",
    "20": "0.81",
    "22": "0.66",
    "24": "0.50",
    "26": "0.40",
    "28": "0.33"
  },
  "sdi_table2_printed_mm": {
    "20": "0.8",
    "18": "1.0",
    "16": "1.3",
    "14": "1.7"
  },
  "statutory_weight_column_oz_sqft": {
    "3": 160,
    "4": 150,
    "5": 140,
    "6": 130,
    "7": 120,
    "8": 110,
    "9": 100,
    "10": 90,
    "11": 80,
    "12": 70,
    "13": 60,
    "14": 50,
    "15": 45,
    "16": 40,
    "17": 36,
    "18": 32,
    "19": 28,
    "20": 24,
    "21": 22,
    "22": 20,
    "23": 18,
    "24": 16,
    "25": 14,
    "26": 12,
    "27": 11,
    "28": 10,
    "29": 9,
    "30": 8
  },
  "clopay_weight_conversion_constant_oz_sqft_per_in": "669.12",
  "sdi_reference_coating_inches_per_oz_sqft_both_sides": "0.0017",
  "coating_selection_gauges": [
    8,
    10,
    12,
    14,
    16,
    18,
    20,
    22,
    24,
    26,
    28
  ],
  "dasma_coating_reference": {
    "G-10": {
      "weight_oz_sqft_both_sides": "0.10",
      "published_increment_in": "0.0002"
    },
    "G-30": {
      "weight_oz_sqft_both_sides": "0.30",
      "published_increment_in": "0.0005"
    },
    "G-40": {
      "weight_oz_sqft_both_sides": "0.40",
      "published_increment_in": "0.0007"
    },
    "G-60": {
      "weight_oz_sqft_both_sides": "0.60",
      "published_increment_in": "0.0010"
    },
    "G-90": {
      "weight_oz_sqft_both_sides": "0.90",
      "published_increment_in": "0.0015"
    }
  },
  "reference_note": "Transcribed source inputs and clause selections checked September 16, 2026; running the accompanying script does not repeat the external-source verification or advance its date.",
  "endurance_qualification_inputs": [
    {
      "standard": "ANSI/SDI A250.8-2023 + A250.4-2026",
      "class_name": "Level 1, performance C",
      "door_face_min_in": ".032",
      "frame_min_in": ".042",
      "cycles_required": "250000",
      "max_twist_in_at_300lb": "2.5",
      "max_permanent_deformation_in": ".125",
      "scope": "Models 1 and 2; representative assembly qualification, not each delivered door",
      "frame_scope": "A250.8 Table 3",
      "edition_scope": "Current cited SDI editions; not a claim about editions incorporated in a particular contract"
    },
    {
      "standard": "ANSI/SDI A250.8-2023 + A250.4-2026",
      "class_name": "Level 2, performance B",
      "door_face_min_in": ".042",
      "frame_min_in": ".053",
      "cycles_required": "500000",
      "max_twist_in_at_300lb": "1.25",
      "max_permanent_deformation_in": ".125",
      "scope": "Models 1 and 2; representative assembly qualification, not each delivered door",
      "frame_scope": "A250.8 Table 3",
      "edition_scope": "Current cited SDI editions; not a claim about editions incorporated in a particular contract"
    },
    {
      "standard": "ANSI/SDI A250.8-2023 + A250.4-2026",
      "class_name": "Level 3, performance A",
      "door_face_min_in": ".053",
      "frame_min_in": ".053",
      "cycles_required": "1000000",
      "max_twist_in_at_300lb": "1.25",
      "max_permanent_deformation_in": ".125",
      "scope": "Models 1 and 2; representative assembly qualification, not each delivered door",
      "frame_scope": "A250.8 Table 3",
      "edition_scope": "Current cited SDI editions; not a claim about editions incorporated in a particular contract"
    },
    {
      "standard": "ANSI/SDI A250.8-2023 + A250.4-2026",
      "class_name": "Level 4, performance A",
      "door_face_min_in": ".067",
      "frame_min_in": ".067",
      "cycles_required": "1000000",
      "max_twist_in_at_300lb": "1.25",
      "max_permanent_deformation_in": ".125",
      "scope": "Models 1 and 2; representative assembly qualification, not each delivered door",
      "frame_scope": "A250.8 Table 3",
      "edition_scope": "Current cited SDI editions; not a claim about editions incorporated in a particular contract"
    },
    {
      "standard": "NAAMM HMMA 861-14",
      "class_name": ".042-in face-sheet tier",
      "door_face_min_in": ".042",
      "frame_min_in": ".053",
      "cycles_required": "1000000",
      "max_twist_in_at_300lb": "1.25",
      "max_permanent_deformation_in": ".125",
      "scope": "Tier is based on face-sheet thickness, not exclusively interior/exterior location; representative assembly",
      "frame_scope": ".067 in required for single doors >4 ft wide, pairs with either leaf >4 ft, or nominal opening height >10 ft",
      "edition_scope": "HMMA 861-14 cites A250.4 under its 2014 reference-edition rule; not asserted identical to A250.4-2026"
    },
    {
      "standard": "NAAMM HMMA 861-14",
      "class_name": ".053-in-and-thicker face-sheet tier",
      "door_face_min_in": ".053",
      "frame_min_in": ".053",
      "cycles_required": "4000000",
      "max_twist_in_at_300lb": ".625",
      "max_permanent_deformation_in": ".062",
      "scope": "Tier is based on face-sheet thickness, not exclusively interior/exterior location; representative assembly",
      "frame_scope": ".067 in required for single doors >4 ft wide, pairs with either leaf >4 ft, or nominal opening height >10 ft",
      "edition_scope": "HMMA 861-14 cites A250.4 under its 2014 reference-edition rule; not asserted identical to A250.4-2026"
    }
  ],
  "component_clause_inputs": [
    {
      "standard": "NAAMM HMMA 861-14",
      "component": "Grout guard",
      "min_thickness_in": "0.016",
      "clause": "Sec 2.03.B.17",
      "qualification": "At hardware mortises on frame product to be grouted."
    },
    {
      "standard": "NAAMM HMMA 861-14",
      "component": "Vertical door stiffener",
      "min_thickness_in": "0.026",
      "clause": "Sec 2.01.B.6",
      "qualification": "Applies to the component and construction specified in the cited clause."
    },
    {
      "standard": "NAAMM HMMA 861-14",
      "component": "Glazing stop or moulding",
      "min_thickness_in": "0.032",
      "clause": "Sec 2.01.B.11",
      "qualification": "Where specified/scheduled; fire-rated door glazing remains subject to the manufacturer’s fire-rating procedure."
    },
    {
      "standard": "NAAMM HMMA 861-14",
      "component": "Frame in-fill panel",
      "min_thickness_in": "0.032",
      "clause": "Sec 2.03.B.19",
      "qualification": "Where specified; .032-in steel is laminated to each face of the specified backing, with approved backing for fire-rated frames."
    },
    {
      "standard": "ANSI/SDI A250.8-2023",
      "component": "Door end channel or closure, all levels",
      "min_thickness_in": "0.042",
      "clause": "Sec 2.3.1.4",
      "qualification": "Applies to the component and construction specified in the cited clause."
    },
    {
      "standard": "ANSI/SDI A250.8-2023",
      "component": "Stile and rail: centre panel",
      "min_thickness_in": "0.042",
      "clause": "Sec 2.3.3",
      "qualification": "Applies to the component and construction specified in the cited clause."
    },
    {
      "standard": "ANSI/SDI A250.8-2023",
      "component": "Frame anchor, sheet type",
      "min_thickness_in": "0.042",
      "clause": "Sec 2.4.4",
      "qualification": "Other than slip-on drywall; cited clause also permits .167-in-diameter wire anchors."
    },
    {
      "standard": "ANSI/SDI A250.8-2023",
      "component": "Frame base anchor",
      "min_thickness_in": "0.042",
      "clause": "Sec 2.4.4.2",
      "qualification": "Other than slip-on drywall; cited clause provides an additional-jamb-anchor alternative where floor anchoring cannot be used."
    },
    {
      "standard": "NAAMM HMMA 861-14",
      "component": "Louver vane, welded V, Y or Z type",
      "min_thickness_in": "0.042",
      "clause": "Sec 2.01.B.12",
      "qualification": "Welded inverted-V, Y or Z louvers for non-fire-protection-rated doors; fire-rated doors require listed louvers."
    },
    {
      "standard": "NAAMM HMMA 861-14",
      "component": "Drywall jamb anchor",
      "min_thickness_in": "0.042",
      "clause": "Sec 2.03.B.15.c",
      "qualification": "Applies to the component and construction specified in the cited clause."
    },
    {
      "standard": "ANSI/SDI A250.8-2023",
      "component": "Stile and rail: stiles and rails",
      "min_thickness_in": "0.053",
      "clause": "Sec 2.3.3",
      "qualification": "Applies to the component and construction specified in the cited clause."
    },
    {
      "standard": "ANSI/SDI A250.8-2023",
      "component": "Pull plate and bar reinforcing",
      "min_thickness_in": "0.053",
      "clause": "Table 4",
      "qualification": "Table 4 note 3 permits omission of reinforcement with the specified through-bolting arrangement."
    },
    {
      "standard": "NAAMM HMMA 861-14",
      "component": "Door top and bottom closure channel",
      "min_thickness_in": "0.053",
      "clause": "Sec 2.01.B.7",
      "qualification": "Applies to the component and construction specified in the cited clause."
    },
    {
      "standard": "NAAMM HMMA 861-14",
      "component": "Masonry jamb anchor, strap or stirrup",
      "min_thickness_in": "0.053",
      "clause": "Sec 2.03.B.15.b",
      "qualification": "Applies to the component and construction specified in the cited clause."
    },
    {
      "standard": "ANSI/SDI A250.8-2023",
      "component": "Mortise or bored lock reinforcing",
      "min_thickness_in": "0.067",
      "clause": "Table 4",
      "qualification": "Table 4 note 1 permits thinner reinforcement with extruded/tapped holes providing equivalent thread engagement."
    },
    {
      "standard": "ANSI/SDI A250.8-2023",
      "component": "Surface exit device reinforcing",
      "min_thickness_in": "0.067",
      "clause": "Table 4",
      "qualification": "Table 4 note 3 permits omission of reinforcement with the specified through-bolting arrangement."
    },
    {
      "standard": "NAAMM HMMA 861-14",
      "component": "Frame, single door >4 ft wide, pair with either leaf >4 ft, or nominal opening height >10 ft",
      "min_thickness_in": "0.067",
      "clause": "Sec 2.03.B.2",
      "qualification": "Width trigger is the individual door leaf, not the combined width of a pair."
    },
    {
      "standard": "NAAMM HMMA 861-14",
      "component": "Other surface-mounted hardware reinforcing",
      "min_thickness_in": "0.067",
      "clause": "Sec 2.01.B.10.e",
      "qualification": "Applies to the component and construction specified in the cited clause."
    },
    {
      "standard": "ANSI/SDI A250.8-2023",
      "component": "Mortise hinge reinforcing, 1-3/8 in door",
      "min_thickness_in": "0.093",
      "clause": "Table 4",
      "qualification": "Table 4 note 1 permits thinner reinforcement with extruded/tapped holes providing equivalent thread engagement."
    },
    {
      "standard": "NAAMM HMMA 861-14",
      "component": "Head stiffener, masonry opening over 48 in",
      "min_thickness_in": "0.093",
      "clause": "Sec 2.03.B.16",
      "qualification": "Steel angle/channel head stiffener for frame product installed in masonry; not a lintel or load-bearing member."
    },
    {
      "standard": "NAAMM HMMA 861-14",
      "component": "Lock front and strike reinforcing",
      "min_thickness_in": "0.093",
      "clause": "Sec 2.01.B.10.e",
      "qualification": "Also permits .053-in unitized reinforcement with extruded/tapped holes providing an equivalent number of threads."
    },
    {
      "standard": "ANSI/SDI A250.8-2023",
      "component": "Mortise hinge reinforcing, 1-3/4 in door",
      "min_thickness_in": "0.123",
      "clause": "Table 4",
      "qualification": "Table 4 notes 1–2 permit thinner extruded/tapped reinforcement with equivalent threads, or .093-in angular/channel reinforcement."
    },
    {
      "standard": "ANSI/SDI A250.8-2023",
      "component": "Floor checking hinge and pivot reinforcing",
      "min_thickness_in": "0.167",
      "clause": "Table 4",
      "qualification": "Applies to the component and construction specified in the cited clause."
    }
  ]
}