  "verified_on": "2026-09-16",
  "input_column_definitions": {
    "C12": [
      "buildings_thousand",
      "all_floorspace_million_sqft",
      "major_fuels_trillion_btu",
      "site_gross_mean_kbtu_per_sqft_year",
      "site_p25_kbtu_per_sqft_year",
      "site_median_kbtu_per_sqft_year",
      "site_p75_kbtu_per_sqft_year",
      "buildings_rse_percent",
      "floorspace_rse_percent",
      "major_fuels_total_rse_percent",
      "site_gross_mean_rse_percent"
    ],
    "C22": [
      "electricity_using_buildings_thousand",
      "electricity_using_floorspace_million_sqft",
      "electricity_total_billion_kwh",
      "electricity_conditional_mean_kwh_per_sqft_year",
      "electricity_p25_kwh_per_sqft_year",
      "electricity_median_kwh_per_sqft_year",
      "electricity_p75_kwh_per_sqft_year",
      "electricity_total_rse_percent",
      "electricity_conditional_mean_rse_percent"
    ],
    "C32": [
      "gas_using_buildings_thousand",
      "gas_using_floorspace_million_sqft",
      "gas_total_billion_cubic_feet",
      "gas_conditional_mean_cubic_feet_per_sqft_year",
      "gas_p25_cubic_feet_per_sqft_year",
      "gas_median_cubic_feet_per_sqft_year",
      "gas_p75_cubic_feet_per_sqft_year"
    ]
  },
  "benchmark_rows": [
    [
      "all_warehouse_storage",
      "Warehouse and storage",
      "total",
      null,
      [
        1004,
        17483,
        528,
        30.2,
        2.2,
        14.0,
        35.2,
        7.4,
        7.2,
        8.3,
        4.9
      ],
      [
        792,
        16335,
        95,
        5.8,
        1.6,
        3.4,
        7.8,
        9.0,
        5.4
      ],
      [
        320,
        10309,
        192,
        18.6,
        9.0,
        22.0,
        38.1
      ]
    ],
    [
      "nonrefrigerated_aggregate",
      "Nonrefrigerated (aggregate)",
      "subtotal",
      "all_warehouse_storage",
      [
        1001,
        17155,
        493,
        28.8,
        2.2,
        14.0,
        35.2,
        7.4,
        7.2,
        8.4,
        4.8
      ],
      [
        788,
        16008,
        85,
        5.3,
        1.6,
        3.4,
        7.7,
        8.8,
        4.9
      ],
      [
        318,
        10113,
        190,
        18.8,
        9.0,
        22.0,
        38.7
      ]
    ],
    [
      "nonrefrigerated_warehouse",
      "Nonrefrigerated: warehouse",
      "leaf",
      "nonrefrigerated_aggregate",
      [
        548,
        7050,
        184,
        26.1,
        5.5,
        18.8,
        40.1,
        9.3,
        10.6,
        10.7,
        6.4
      ],
      [
        476,
        6661,
        31,
        4.7,
        1.6,
        3.5,
        7.9,
        12.2,
        6.6
      ],
      [
        193,
        3579,
        73,
        20.4,
        12.1,
        22.0,
        41.9
      ]
    ],
    [
      "distribution_shipping",
      "Distribution or shipping center",
      "leaf",
      "nonrefrigerated_aggregate",
      [
        167,
        7998,
        275,
        34.4,
        15.1,
        27.6,
        52.6,
        14.1,
        9.5,
        10.9,
        5.6
      ],
      [
        161,
        7985,
        47,
        5.9,
        2.9,
        4.6,
        7.8,
        10.6,
        6.5
      ],
      [
        100,
        6009,
        107,
        17.7,
        6.3,
        23.1,
        33.8
      ]
    ],
    [
      "self_storage",
      "Self storage units",
      "leaf",
      "nonrefrigerated_aggregate",
      [
        285,
        2107,
        34,
        16.2,
        0.0,
        2.1,
        5.5,
        18.1,
        19.4,
        33.4,
        22.9
      ],
      [
        152,
        1362,
        7,
        5.1,
        1.0,
        1.6,
        7.0,
        31.3,
        17.3
      ],
      [
        "Q",
        "Q",
        "Q",
        "Q",
        "Q",
        "Q",
        "Q"
      ]
    ],
    [
      "refrigerated",
      "Refrigerated warehouse",
      "leaf",
      "all_warehouse_storage",
      [
        3,
        327,
        35,
        107.0,
        105.8,
        113.5,
        147.7,
        44.7,
        27.7,
        33.9,
        18.5
      ],
      [
        3,
        327,
        10,
        29.6,
        30.9,
        30.9,
        37.5,
        34.7,
        19.4
      ],
      [
        "Q",
        "Q",
        "Q",
        "Q",
        "Q",
        "Q",
        "Q"
      ]
    ]
  ],
  "regional_rows": [
    [
      "New England",
      12,
      469,
      25.1,
      33.2,
      23.5,
      15.3,
      "C7",
      "Connecticut|Maine|Massachusetts|New Hampshire|Rhode Island|Vermont"
    ],
    [
      "Middle Atlantic",
      72,
      1929,
      37.5,
      20.5,
      20.7,
      6.3,
      "C7",
      "New Jersey|New York|Pennsylvania"
    ],
    [
      "East North Central",
      121,
      3402,
      35.6,
      15.8,
      15.1,
      8.6,
      "C7",
      "Illinois|Indiana|Michigan|Ohio|Wisconsin"
    ],
    [
      "West North Central",
      56,
      1312,
      42.3,
      38.3,
      22.0,
      19.9,
      "C8",
      "Iowa|Kansas|Minnesota|Missouri|Nebraska|North Dakota|South Dakota"
    ],
    [
      "South Atlantic",
      83,
      3034,
      27.5,
      21.4,
      17.8,
      10.4,
      "C8",
      "Delaware|District of Columbia|Florida|Georgia|Maryland|North Carolina|South Carolina|Virginia|West Virginia"
    ],
    [
      "East South Central",
      38,
      1250,
      30.1,
      39.9,
      40.1,
      10.2,
      "C8",
      "Alabama|Kentucky|Mississippi|Tennessee"
    ],
    [
      "West South Central",
      56,
      2080,
      27.1,
      20.0,
      24.9,
      17.7,
      "C9",
      "Arkansas|Louisiana|Oklahoma|Texas"
    ],
    [
      "Mountain",
      31,
      1049,
      29.2,
      35.6,
      25.5,
      14.5,
      "C9",
      "Arizona|Colorado|Idaho|Montana|Nevada|New Mexico|Utah|Wyoming"
    ],
    [
      "Pacific",
      60,
      2958,
      20.1,
      20.1,
      17.9,
      14.9,
      "C9",
      "Alaska|California|Hawaii|Oregon|Washington"
    ]
  ],
  "end_use_rows": [
    [
      "Space heating",
      208,
      15.8
    ],
    [
      "Cooling",
      52,
      3.9
    ],
    [
      "Ventilation",
      24,
      1.7
    ],
    [
      "Water heating",
      7,
      0.5
    ],
    [
      "Lighting",
      80,
      5.1
    ],
    [
      "Cooking",
      1,
      0.5
    ],
    [
      "Refrigeration",
      36,
      3.3
    ],
    [
      "Office equipment",
      2,
      0.1
    ],
    [
      "Computing",
      8,
      0.6
    ],
    [
      "Other",
      111,
      6.8
    ]
  ],
  "version": "1.0.0",
  "publisher": "Milwaukee Dock Door Repair Research",
  "source_urls": {
    "C12": "https://www.eia.gov/consumption/commercial/data/2018/ce/pdf/c12.pdf",
    "C22": "https://www.eia.gov/consumption/commercial/data/2018/ce/pdf/c22.pdf",
    "C32": "https://www.eia.gov/consumption/commercial/data/2018/ce/pdf/c32.pdf",
    "E1": "https://www.eia.gov/consumption/commercial/data/2018/ce/pdf/e1.pdf",
    "E2": "https://www.eia.gov/consumption/commercial/data/2018/ce/pdf/e2.pdf",
    "C7": "https://www.eia.gov/consumption/commercial/data/2018/ce/pdf/c7.pdf",
    "C8": "https://www.eia.gov/consumption/commercial/data/2018/ce/pdf/c8.pdf",
    "C9": "https://www.eia.gov/consumption/commercial/data/2018/ce/pdf/c9.pdf",
    "B15": "https://www.eia.gov/consumption/commercial/data/2018/bc/html/b15.php",
    "PBA3": "https://www.eia.gov/consumption/commercial/data/2012/c%26e/cfm/pba3.php",
    "PROFILE": "https://www.eia.gov/consumption/commercial/pba/warehouse-and-storage.php",
    "OVERVIEW": "https://www.eia.gov/consumption/commercial/",
    "FAQ": "https://www.eia.gov/consumption/commercial/faq.php",
    "GUIDE": "https://www.eia.gov/consumption/commercial/data/2018/guide.php",
    "MODEL": "https://www.eia.gov/consumption/commercial/reports/2018/estimated-end-use.php",
    "COLLECTION": "https://www.eia.gov/consumption/commercial/reports/2018/data-collection-buildings.php",
    "SUSPENSION": "https://www.eia.gov/pressroom/releases/press362.php",
    "CENSUS": "https://www.census.gov/programs-surveys/economic-census/geographies/levels/2022-levels.html",
    "EPA": "https://portfoliomanager.energystar.gov/pdf/reference/US%20National%20Median%20Table.pdf",
    "EPAMODEL": "https://www.energystar.gov/buildings/tools-and-resources/energy-star-score-warehouses",
    "EPAPDF": "https://www.energystar.gov/sites/default/files/tools/Warehouse_August_2018_EN_508.pdf",
    "CONVERSION": "https://www.eia.gov/energyexplained/units-and-calculators/energy-conversion-calculators.php",
    "PRICE": "https://www.eia.gov/electricity/sales_revenue_price/pdf/table_5B.pdf",
    "SEATTLE": "https://www.seattle.gov/documents/Departments/SDCI/Codes/SeattleEnergyCode/2015SECCommercialChapter4.pdf",
    "NYC": "https://www.nyc.gov/assets/buildings/codes-pdf/energy_code_2016/2016ECC_CHC4.pdf",
    "IECC2012": "https://codes.iccsafe.org/content/IECC2012P5/index-ce-",
    "IECC2015": "https://codes.iccsafe.org/s/IECC2015NY/chapter-4-ce-commercial-energy-efficiency/IECC2015-Pt01-Ch04-SecC402.5.6",
    "IECC2018INDEX": "https://codes.iccsafe.org/content/NHECC2018P1/index",
    "IECC2021": "https://codes.iccsafe.org/content/IECC2021V3.0/chapter-4-ce-commercial-energy-efficiency",
    "ASHRAE": "https://www.ashrae.org/technical-resources/bookstore/standard-90-1",
    "ASHRAEPREVIEW": "https://www.ashrae.org/technical-resources/standards-and-guidelines/read-only-versions-of-ashrae-standards",
    "WA2013": "https://lawfilesext.leg.wa.gov/law/wsr/2013/04/13-04-056.htm",
    "WA2019": "https://lawfilesext.leg.wa.gov/law/wsr/2019/24/19-24-040.htm",
    "WAC": "https://app.leg.wa.gov/wac/default.aspx?cite=51-11C-40246",
    "WADELAY": "https://sbcc.wa.gov/news/2018-code-effective-date-extended-february-1-2021",
    "WI": "https://dsps.wi.gov/Pages/Programs/CommercialBuildings/Default.aspx",
    "WIINSERT": "https://dsps.wi.gov/Documents/Programs/CommercialBuildings/SPS363Insert.pdf"
  },
  "btu_per_kwh": 3412,
  "historical": {
    "2012": {
      "major_fuels_trillion_btu": 429,
      "floorspace_million_sqft": 13077,
      "gross_mean_kbtu_sqft": 32.8
    },
    "2018": {
      "major_fuels_trillion_btu": 528,
      "floorspace_million_sqft": 17483,
      "gross_mean_kbtu_sqft": 30.2
    }
  },
  "published_per_building": {
    "area_thousand_sqft": [
      17.4,
      17.1,
      12.9,
      47.8,
      7.4,
      94.8
    ],
    "energy_million_btu": [
      526,
      493,
      335,
      1647,
      120,
      10144
    ],
    "area_rse_percent": [
      7.0,
      7.0,
      8.6,
      12.8,
      8.6,
      33.1
    ],
    "energy_per_building_rse_percent": [
      9.1,
      9.0,
      9.6,
      14.2,
      28.0,
      27.5
    ]
  },
  "wisconsin_commercial_electricity_2024": {
    "customers": 369433,
    "average_monthly_kwh": 5255,
    "average_revenue_cents_per_kwh": 12.63,
    "average_monthly_bill_usd": 663.92,
    "source_url": "https://www.eia.gov/electricity/sales_revenue_price/pdf/table_5B.pdf"
  },
  "intensity_ledger": [
    {
      "value_kbtu_sqft_year": 2.1,
      "energy_basis": "site, four major fuels",
      "statistic": "median",
      "population_or_property_type": "Self-storage units",
      "publisher": "EIA",
      "document": "2018 CBECS table C12",
      "document_date": "2022-12",
      "observation_year": "2018",
      "source_url": "https://www.eia.gov/consumption/commercial/data/2018/ce/pdf/c12.pdf",
      "limitation": "",
      "last_verified": "2026-09-16",
      "verification": "primary source checked"
    },
    {
      "value_kbtu_sqft_year": 14,
      "energy_basis": "site, four major fuels",
      "statistic": "median",
      "population_or_property_type": "All warehouse and storage",
      "publisher": "EIA",
      "document": "2018 CBECS table C12",
      "document_date": "2022-12",
      "observation_year": "2018",
      "source_url": "https://www.eia.gov/consumption/commercial/data/2018/ce/pdf/c12.pdf",
      "limitation": "",
      "last_verified": "2026-09-16",
      "verification": "primary source checked"
    },
    {
      "value_kbtu_sqft_year": 18.8,
      "energy_basis": "site, four major fuels",
      "statistic": "median",
      "population_or_property_type": "Nonrefrigerated warehouse",
      "publisher": "EIA",
      "document": "2018 CBECS table C12",
      "document_date": "2022-12",
      "observation_year": "2018",
      "source_url": "https://www.eia.gov/consumption/commercial/data/2018/ce/pdf/c12.pdf",
      "limitation": "",
      "last_verified": "2026-09-16",
      "verification": "primary source checked"
    },
    {
      "value_kbtu_sqft_year": 20.2,
      "energy_basis": "site",
      "statistic": "median",
      "population_or_property_type": "Self-Storage Facility",
      "publisher": "EPA ENERGY STAR",
      "document": "U.S. Energy Use Intensity by Property Type",
      "document_date": "2024-08",
      "observation_year": "Not specified per row",
      "source_url": "https://portfoliomanager.energystar.gov/pdf/reference/US%20National%20Median%20Table.pdf",
      "limitation": "Peer group identified by EPA as CBECS Non-refrigerated Warehouse; not an EIA self-storage-only estimate",
      "last_verified": "2026-09-16",
      "verification": "primary source checked"
    },
    {
      "value_kbtu_sqft_year": 22.7,
      "energy_basis": "site",
      "statistic": "median",
      "population_or_property_type": "Non-Refrigerated Warehouse and Distribution Center",
      "publisher": "EPA ENERGY STAR",
      "document": "U.S. Energy Use Intensity by Property Type",
      "document_date": "2024-08",
      "observation_year": "Not specified per row",
      "source_url": "https://portfoliomanager.energystar.gov/pdf/reference/US%20National%20Median%20Table.pdf",
      "limitation": "",
      "last_verified": "2026-09-16",
      "verification": "primary source checked"
    },
    {
      "value_kbtu_sqft_year": 26.1,
      "energy_basis": "site, four major fuels",
      "statistic": "gross mean",
      "population_or_property_type": "Nonrefrigerated warehouse",
      "publisher": "EIA",
      "document": "2018 CBECS table C12",
      "document_date": "2022-12",
      "observation_year": "2018",
      "source_url": "https://www.eia.gov/consumption/commercial/data/2018/ce/pdf/c12.pdf",
      "limitation": "",
      "last_verified": "2026-09-16",
      "verification": "primary source checked"
    },
    {
      "value_kbtu_sqft_year": 27.6,
      "energy_basis": "site, four major fuels",
      "statistic": "median",
      "population_or_property_type": "Distribution or shipping center",
      "publisher": "EIA",
      "document": "2018 CBECS table C12",
      "document_date": "2022-12",
      "observation_year": "2018",
      "source_url": "https://www.eia.gov/consumption/commercial/data/2018/ce/pdf/c12.pdf",
      "limitation": "",
      "last_verified": "2026-09-16",
      "verification": "primary source checked"
    },
    {
      "value_kbtu_sqft_year": 30.2,
      "energy_basis": "site, four major fuels",
      "statistic": "gross mean",
      "population_or_property_type": "All warehouse and storage",
      "publisher": "EIA",
      "document": "2018 CBECS table C12",
      "document_date": "2022-12",
      "observation_year": "2018",
      "source_url": "https://www.eia.gov/consumption/commercial/data/2018/ce/pdf/c12.pdf",
      "limitation": "",
      "last_verified": "2026-09-16",
      "verification": "primary source checked"
    },
    {
      "value_kbtu_sqft_year": 34.4,
      "energy_basis": "site, four major fuels",
      "statistic": "gross mean",
      "population_or_property_type": "Distribution or shipping center",
      "publisher": "EIA",
      "document": "2018 CBECS table C12",
      "document_date": "2022-12",
      "observation_year": "2018",
      "source_url": "https://www.eia.gov/consumption/commercial/data/2018/ce/pdf/c12.pdf",
      "limitation": "",
      "last_verified": "2026-09-16",
      "verification": "primary source checked"
    },
    {
      "value_kbtu_sqft_year": 47.8,
      "energy_basis": "source",
      "statistic": "median",
      "population_or_property_type": "Self-Storage Facility",
      "publisher": "EPA ENERGY STAR",
      "document": "U.S. Energy Use Intensity by Property Type",
      "document_date": "2024-08",
      "observation_year": "Not specified per row",
      "source_url": "https://portfoliomanager.energystar.gov/pdf/reference/US%20National%20Median%20Table.pdf",
      "limitation": "Peer group identified by EPA as CBECS Non-refrigerated Warehouse; not an EIA self-storage-only estimate",
      "last_verified": "2026-09-16",
      "verification": "primary source checked"
    },
    {
      "value_kbtu_sqft_year": 52.9,
      "energy_basis": "source",
      "statistic": "median",
      "population_or_property_type": "Non-Refrigerated Warehouse and Distribution Center",
      "publisher": "EPA ENERGY STAR",
      "document": "U.S. Energy Use Intensity by Property Type",
      "document_date": "2024-08",
      "observation_year": "Not specified per row",
      "source_url": "https://portfoliomanager.energystar.gov/pdf/reference/US%20National%20Median%20Table.pdf",
      "limitation": "",
      "last_verified": "2026-09-16",
      "verification": "primary source checked"
    },
    {
      "value_kbtu_sqft_year": 84.1,
      "energy_basis": "site",
      "statistic": "median",
      "population_or_property_type": "Refrigerated Warehouse",
      "publisher": "EPA ENERGY STAR",
      "document": "U.S. Energy Use Intensity by Property Type",
      "document_date": "2024-08",
      "observation_year": "Not specified per row",
      "source_url": "https://portfoliomanager.energystar.gov/pdf/reference/US%20National%20Median%20Table.pdf",
      "limitation": "Do not assign the score-model reference year to this summary-table median without documentation",
      "last_verified": "2026-09-16",
      "verification": "primary source checked"
    },
    {
      "value_kbtu_sqft_year": 107,
      "energy_basis": "site, four major fuels",
      "statistic": "gross mean",
      "population_or_property_type": "Refrigerated warehouse",
      "publisher": "EIA",
      "document": "2018 CBECS table C12",
      "document_date": "2022-12",
      "observation_year": "2018",
      "source_url": "https://www.eia.gov/consumption/commercial/data/2018/ce/pdf/c12.pdf",
      "limitation": "",
      "last_verified": "2026-09-16",
      "verification": "primary source checked"
    },
    {
      "value_kbtu_sqft_year": 113.5,
      "energy_basis": "site, four major fuels",
      "statistic": "median",
      "population_or_property_type": "Refrigerated warehouse",
      "publisher": "EIA",
      "document": "2018 CBECS table C12",
      "document_date": "2022-12",
      "observation_year": "2018",
      "source_url": "https://www.eia.gov/consumption/commercial/data/2018/ce/pdf/c12.pdf",
      "limitation": "",
      "last_verified": "2026-09-16",
      "verification": "primary source checked"
    },
    {
      "value_kbtu_sqft_year": 235.6,
      "energy_basis": "source",
      "statistic": "median",
      "population_or_property_type": "Refrigerated Warehouse",
      "publisher": "EPA ENERGY STAR",
      "document": "U.S. Energy Use Intensity by Property Type",
      "document_date": "2024-08",
      "observation_year": "Not specified per row",
      "source_url": "https://portfoliomanager.energystar.gov/pdf/reference/US%20National%20Median%20Table.pdf",
      "limitation": "",
      "last_verified": "2026-09-16",
      "verification": "primary source checked"
    }
  ],
  "code_crosswalk": [
    {
      "jurisdiction_or_publication": "IECC",
      "edition_or_cycle": "2012",
      "section": "C402.4.6",
      "verified_statement": "Section identified in publisher index; model-code wording not reproduced",
      "effective_date_or_edition": "2012 edition",
      "verification_scope": "Index location only",
      "source_urls": "https://codes.iccsafe.org/content/IECC2012P5/index-ce-",
      "last_verified": "2026-09-16"
    },
    {
      "jurisdiction_or_publication": "IECC",
      "edition_or_cycle": "2015",
      "section": "C402.5.6",
      "verified_statement": "Weatherseals limit infiltration when vehicles are parked in the doorway",
      "effective_date_or_edition": "2015 edition",
      "verification_scope": "Requirement text checked",
      "source_urls": "https://codes.iccsafe.org/s/IECC2015NY/chapter-4-ce-commercial-energy-efficiency/IECC2015-Pt01-Ch04-SecC402.5.6; https://www.seattle.gov/documents/Departments/SDCI/Codes/SeattleEnergyCode/2015SECCommercialChapter4.pdf",
      "last_verified": "2026-09-16"
    },
    {
      "jurisdiction_or_publication": "2018 IECC / New Hampshire publisher index",
      "edition_or_cycle": "2018",
      "section": "C402.5.6",
      "verified_statement": "Index identifies the loading-dock subsection; unamended model wording not reproduced",
      "effective_date_or_edition": "2018 edition index with New Hampshire amendments",
      "verification_scope": "Index location only",
      "source_urls": "https://codes.iccsafe.org/content/NHECC2018P1/index",
      "last_verified": "2026-09-16"
    },
    {
      "jurisdiction_or_publication": "IECC",
      "edition_or_cycle": "2021",
      "section": "C402.5.8",
      "verified_statement": "Weatherseals limit infiltration and contact the top and sides of parked vehicles",
      "effective_date_or_edition": "2021 edition",
      "verification_scope": "Requirement text checked",
      "source_urls": "https://codes.iccsafe.org/content/IECC2021V3.0/chapter-4-ce-commercial-energy-efficiency",
      "last_verified": "2026-09-16"
    },
    {
      "jurisdiction_or_publication": "ANSI/ASHRAE/IES 90.1",
      "edition_or_cycle": "2025",
      "section": "",
      "verified_statement": "Edition confirmed; a weatherseal section number or requirement is not asserted from the accessible publisher material",
      "effective_date_or_edition": "2025 edition",
      "verification_scope": "Edition existence only; requirement excluded",
      "source_urls": "https://www.ashrae.org/technical-resources/bookstore/standard-90-1; https://www.ashrae.org/technical-resources/standards-and-guidelines/read-only-versions-of-ashrae-standards",
      "last_verified": "2026-09-16"
    },
    {
      "jurisdiction_or_publication": "Washington",
      "edition_or_cycle": "2013 effective cycle",
      "section": "C402.4.6",
      "verified_statement": "Weatherseals limit infiltration when vehicles are parked in the doorway",
      "effective_date_or_edition": "2013-07-01",
      "verification_scope": "Requirement text and effective date checked",
      "source_urls": "https://lawfilesext.leg.wa.gov/law/wsr/2013/04/13-04-056.htm",
      "last_verified": "2026-09-16"
    },
    {
      "jurisdiction_or_publication": "Washington",
      "edition_or_cycle": "2015 code cycle",
      "section": "C402.5.6",
      "verified_statement": "Weatherseals limit infiltration when vehicles are parked in the doorway",
      "effective_date_or_edition": "2016-07-01",
      "verification_scope": "Prior text in official amendment and effective-date history checked",
      "source_urls": "https://lawfilesext.leg.wa.gov/law/wsr/2019/24/19-24-040.htm; https://app.leg.wa.gov/wac/default.aspx?cite=51-11C-40246",
      "last_verified": "2026-09-16"
    },
    {
      "jurisdiction_or_publication": "Washington",
      "edition_or_cycle": "2018 code cycle",
      "section": "C402.5.6",
      "verified_statement": "Weatherseals limit infiltration and contact the top and sides of parked vehicles",
      "effective_date_or_edition": "2021-02-01; original 2019 rule filing specified 2020-07-01 before postponement",
      "verification_scope": "Requirement and revised effective date checked",
      "source_urls": "https://lawfilesext.leg.wa.gov/law/wsr/2019/24/19-24-040.htm; https://sbcc.wa.gov/news/2018-code-effective-date-extended-february-1-2021",
      "last_verified": "2026-09-16"
    },
    {
      "jurisdiction_or_publication": "Washington",
      "edition_or_cycle": "2021 code cycle",
      "section": "C402.5.8",
      "verified_statement": "Weatherseals limit infiltration and contact the top and sides of parked vehicles",
      "effective_date_or_edition": "2024-03-15",
      "verification_scope": "Current rule text and effective date checked",
      "source_urls": "https://app.leg.wa.gov/wac/default.aspx?cite=51-11C-40246",
      "last_verified": "2026-09-16"
    },
    {
      "jurisdiction_or_publication": "Wisconsin",
      "edition_or_cycle": "2015 IECC prior base",
      "section": "C402.5.6",
      "verified_statement": "Prior IECC provision; eligibility for a project depends on the state transition",
      "effective_date_or_edition": "Prior base; transition permitted previous-code submittals before 2025-11-01",
      "verification_scope": "Prior-base transition and adopted-code wording checked",
      "source_urls": "https://dsps.wi.gov/Pages/Programs/CommercialBuildings/Default.aspx; https://codes.iccsafe.org/s/IECC2015NY/chapter-4-ce-commercial-energy-efficiency/IECC2015-Pt01-Ch04-SecC402.5.6",
      "last_verified": "2026-09-16"
    },
    {
      "jurisdiction_or_publication": "Wisconsin",
      "edition_or_cycle": "2021 IECC base",
      "section": "C402.5.8",
      "verified_statement": "Weatherseals contact the top and sides of parked vehicles; SPS 363.0402 does not delete this subsection",
      "effective_date_or_edition": "Adopted 2025-09-01; mandatory for plans submitted on or after 2025-11-01",
      "verification_scope": "Adoption, state amendment and model provision checked",
      "source_urls": "https://dsps.wi.gov/Pages/Programs/CommercialBuildings/Default.aspx; https://dsps.wi.gov/Documents/Programs/CommercialBuildings/SPS363Insert.pdf; https://codes.iccsafe.org/content/IECC2021V3.0/chapter-4-ce-commercial-energy-efficiency",
      "last_verified": "2026-09-16"
    }
  ]
}